What precautions should be taken when installing the air starter motor?
Release time:
2021-03-03
Compared to motors with the same function, the characteristics of air-start motors are that the casing is lightweight and easy to transport; moreover, since its working medium is air, there is no need to worry about causing a fire; when the pneumatic motor is overloaded, it can automatically stop operating and maintain balance with the supplied pressure. Due to these characteristics, pneumatic motors are widely used in mining machinery, flammable and explosive liquids, and pneumatic tools. However, it is also necessary to pay attention, especially during installation. Below, the editor will introduce some preventive measures to take during installation.
Compared to motors with the same function,air starting motorits characteristics include a lightweight shell and convenient transportation; moreover, since its working medium is air, there is no need to worry about causing a fire; when overloaded, the pneumatic motor can automatically stop running and maintain balance with the supply pressure. Due to these characteristics, pneumatic motors are widely used in mining machinery, flammable and explosive liquids, and pneumatic tools. However, it is also important to pay attention, especially during installation. Below, the editor will introduce some preventive measures to take during installation.
1.air starting motorThe main failure is the entry of dust, dirt, oily or watery dirty air, or other liquid substances into the motor, leading to unstable operation. When installing pipes, the pipes must be cleaned, and care must be taken not to let foreign objects such as cutting powder and sealing tape enter the pipes.
2. Changing the diameter of the air pipe is not allowed; only by ensuring sufficient air intake can the desired effect be achieved.
3. Install an oil-water separator on the intake pipeline to protectair starting motor.
4. It is strictly forbidden to continue using after disassembly; the lack of components can lead to failures in the pneumatic motor, which can more easily endanger the safety of the operator.
5. During use, handle with care, do not operate with faults, and avoid irregular operations such as throwing, dropping, or smashing.
6. Do not run at high speed for long periods without a load, as this may shorten the lifespan of the pneumatic motor.
7. Whenair starting motorrunning at high speed, do not hold the driven object with your hand to avoid personal injury due to excessive speed.
8. Speed control and stability must be adjusted from the air supply end, so that there will be no back pressure at the exhaust end.
9. When the air starting motor is running, an air source triplet must be installed, and the oil mist generator needs to ensure normal oil supply.